What PGW asks after a storm
Before winter storms, PGW reminds customers to check that the exhaust vents of high-efficiency gas equipment vented outside, like a furnace, a boiler or a water heater, are clear of snow and ice. If the gas meter is outside, PGW asks that it be kept clear too, for access in an emergency and so the meter keeps working properly.
PGW runs around the clock. If you smell gas at any point, leave the area and call PGW at (215) 235-1212.
Find your vents before it snows
- High-efficiency boilers and water heaters vent through plastic pipes, white or gray, that come out of a side or back wall, often in pairs: one brings air in, one takes exhaust out.
- They are often low on the wall, right where snow drifts and where shoveled snow ends up.
- Older boilers and water heaters vent through a chimney or a metal pipe through the roof instead.
- The dryer vent is on an outside wall too, and needs the same attention.
- Mark low vents with a stake or a flag, so you can find them under a drift.
Clearing them safely
Use a broom or your hands
Brush the snow away from both pipes. A shovel or an ice pick can crack plastic vent pipe.
Clear around them, not only the openings
Leave open space around the pipes so exhaust can leave and fresh air can come in without mixing.
Keep shoveled snow away
Don’t pile snow from the sidewalk or the steps against the wall where the vents are.
Check again later
Drifting, plowing and snow sliding off the roof can cover them again. Look after each round of snow.
Check the appliance
If the boiler or water heater shut off while the vent was blocked, it may need a restart. Follow the manual, and call if it doesn’t run.
Safety first. If a CO alarm sounds, don’t go looking for the vent. Get everyone outside and call 911, then PGW. Our guide on carbon monoxide alarms explains the next steps.
The gas meter
If your meter is outside, brush the snow off it gently by hand or with a broom, and don’t bury it when you shovel. Keep a path to it open, because PGW or the fire department may need to reach it fast. Ice dripping from the roof onto the meter is worth watching too.
Never use a shovel, salt, hot water or a chisel on the meter or its piping. If the meter looks damaged, or you smell gas near it, leave and call PGW.
Snow and ice from the roof
Snow sliding off a roof can land right on a meter or a vent and bury it in seconds, and icicles above a vent drip and freeze over the opening. After a thaw-and-freeze day, look up as well as down: knock down icicles hanging over the vents or the meter from a safe spot, and clear what fell.
Signs a vent is blocked
- The boiler or water heater stopped during or after the snow, or shows an error or a lockout.
- No heat or no hot water, with power and gas available.
- A CO alarm sounds.
- An exhaust smell near the boiler or the water heater.
- The appliance starts, runs for a minute and shuts off again.
A tankless water heater on an outside wall has the same risk. See a tankless water heater that froze.
Chimney-vented boilers and water heaters
Older boilers and water heaters send their exhaust up a chimney instead of through the wall. Snow rarely closes the top of a chimney, but ice, a collapsed liner or debris can, and a blocked chimney spills exhaust into the basement at the appliance. That is why a working CO alarm near the boiler matters most in an older house, and why the chimney gets checked during the yearly boiler service.
A quick after-the-storm round
- Boiler and water heater vents clear, intake and exhaust.
- Gas meter and the path to it clear, if the meter is outside.
- Dryer vent clear.
- Downspouts and the area around them clear, so meltwater runs away from the house.
- Outdoor faucets still shut off and drained.
- Heat and hot water working.
What to tell the plumber when you call
- Whether the boiler or water heater is a high-efficiency model with plastic vent pipes.
- Whether the vents were buried, and whether you cleared them.
- What the appliance does now, and any error code.
- Whether a CO alarm went off.
If the vent pipe looks cracked or pushed out of place after you cleared it, say so. A damaged vent has to be fixed before the appliance runs again.
When to call a plumber
- The boiler or water heater doesn’t restart after the vents are cleared.
- A vent pipe is cracked, crushed or pulled out.
- A CO alarm went off (after the house has been cleared by the fire department or PGW).
- The vents get blocked by every snow and need to be raised.
- The chimney hasn’t been checked in years.
Boiler stopped after snow? Send a request
- A plumber at your door within 1 hour of confirming by phone
- Nights, weekends and holidays
- Anywhere in Philadelphia
Prefer to talk? Call us
Questions people ask
How do I know if my boiler has a vent on the wall?
Look for one or two plastic pipes coming out of the house near the boiler’s side of the basement. If the boiler connects only to a metal pipe going into a chimney, it vents through the chimney.
Can I restart the boiler after clearing the vent?
Often yes, by following the manual’s restart steps. If it locks out again, call: the vent or the boiler may be damaged.
Can a vent be moved so snow doesn’t block it?
Often, within the maker’s rules for vent height and clearances. A plumber can raise it or reroute it.
Is ice on the vent pipe a problem?
Some frost around the exhaust is normal in hard cold. Ice that closes the opening is not: clear it gently, without hitting the pipe.
Do I need to clear the dryer vent too?
Yes. A blocked dryer vent traps hot, moist air and lint, and a gas dryer also sends its exhaust out through it.
Should I cover the vents during a storm?
No. Don’t cover or wrap the vent pipes: anything over the opening can block the exhaust. Keep them open and clear them often.
What if my meter is inside the house?
Then there is nothing to clear outside, but keep the area around it in the basement clear and reachable.