Carbon Monoxide Alarm Near the Boiler or Water Heater: What to Do

If a carbon monoxide alarm is sounding, stop reading: get everyone outside and call 911. Once you are safe, this guide explains why boilers and water heaters can produce CO, what usually causes it and how to prevent it.

5 min read

If the alarm is sounding

  1. Get everyone out

    People and pets, into fresh air. Don’t stop to open windows or look for the cause.

  2. Call 911 from outside

    PGW’s guidance is the same: if you suspect carbon monoxide poisoning, call 911 or emergency medical help immediately.

  3. Stay out

    Don’t go back in until the fire department says it is safe.

  4. Get the appliance checked

    Before the boiler or water heater runs again, have it inspected and the cause fixed.

Safety first. Tell the 911 dispatcher if anyone has a headache, dizziness, nausea or confusion. Those are common signs of carbon monoxide poisoning.

Once everyone is safe: get the boiler or water heater checked

What carbon monoxide is

Carbon monoxide is a colorless, odorless gas made when gas, oil or wood burns with too little air or vents poorly. You can’t see, smell or taste it, which is why only an alarm warns you in time.

Alarm, chirp or end of life?

  • Four quick beeps, a pause, then repeating: carbon monoxide detected. Treat it as real.
  • A single chirp every minute or so: usually a low battery.
  • Chirping from an alarm that has been up for years: many alarms signal the end of their life this way. The date is on the back.
  • Three beeps and a pause on a combination unit is usually the smoke alarm pattern.

Patterns vary by model, so check the label on yours.

How boilers and water heaters cause it

  • A blocked or disconnected vent pipe, so exhaust can’t leave the house.
  • A chimney blocked by debris, a nest or a collapsed liner.
  • Backdrafting: exhaust pulled back into the house when strong fans or a dryer pull air out of a tight basement.
  • A dirty or badly adjusted burner, often with soot or a lazy yellow flame.
  • A cracked heat exchanger in a boiler.
  • A water heater left alone in a chimney sized for an old boiler, which may stop venting properly after the boiler is replaced.

Warning signs besides the alarm

  • Soot or scorch marks around the burner door or the vent.
  • A yellow or orange flame on a gas appliance instead of a crisp blue one.
  • Heavy condensation on windows near the heating equipment.
  • Headaches or nausea that ease when you leave the house.

Preventing it

  • Have the boiler serviced and its combustion tested every year.
  • Have the water heater’s vent checked, especially after any change to the boiler or the chimney.
  • Keep vents, chimneys and intake pipes clear.
  • Never use a gas oven or stove to heat the house.
  • Never run a generator or a charcoal grill indoors or in a garage.

Where the alarms go

PGW recommends at least one smoke and carbon monoxide detector on each floor and replacing CO detector batteries twice a year. Pennsylvania’s Carbon Monoxide Alarm Standards Act also requires CO alarms near the bedrooms and the fuel-burning heater in rental homes that have one.

Symptoms to know

Carbon monoxide symptoms are easy to mistake for the flu: headache, dizziness, weakness, nausea, vomiting, chest pain and confusion. Several people, or pets, feeling unwell at the same time, and feeling better outside, are strong hints.

Testing and looking after alarms

  • Press the test button once a month.
  • Replace batteries as the label says, or twice a year as PGW suggests.
  • Vacuum dust from the alarm’s vents.
  • Replace the whole alarm by the date on its back.

Placement tips

  • Near the bedrooms, where people could sleep through the symptoms.
  • On every floor, including the basement.
  • At the distance from fuel-burning appliances that the alarm’s instructions give, so a brief puff at startup doesn’t set it off.
  • Away from damp bathrooms, windows and fans.

After the fire department leaves

Firefighters measure the levels and may shut off the appliance they suspect. Leave it off. The cause still has to be repaired, and the appliance tested, before it runs again.

Gas stoves and ovens

Gas ranges produce combustion gases too. Use the range hood, or open a window, while cooking, and never use the oven or the burners to heat a room, which PGW also warns against.

What to tell the plumber when you call

  • That a CO alarm went off, when, and where the alarm is.
  • Which appliances run on gas or oil: boiler, water heater, stove, dryer.
  • Any recent change: a new boiler, chimney work, new exhaust fans.
  • Anything you noticed: soot, a smell, a loose vent pipe.

After a CO alarm, the plumber checks every fuel-burning appliance, not just the one closest to the alarm.

After the alarm: get it checked

  • The alarm went off near the boiler or the water heater.
  • You see soot, scorch marks or a yellow flame.
  • The vent pipe is loose, rusted or disconnected.
  • The boiler or chimney was changed and the water heater wasn’t checked.

After a CO alarm: send a request

  • A plumber at your door within 1 hour of confirming by phone
  • Nights, weekends and holidays
  • Anywhere in Philadelphia

Prefer to talk? Call us

Tell us what's wrong

Takes under a minute. For emergencies, someone is at your door within 1 hour of confirming by phone.

How urgent is it?

What a plumber checks after a CO alarm

  • The vent and chimney connection of each gas appliance, for draft and leaks.
  • The burner flame and combustion readings.
  • The boiler’s heat exchanger, for cracks.
  • Whether exhaust fans or a dryer pull exhaust back into the basement.

Questions people ask

Can a water heater give off carbon monoxide?

Yes. Any gas or oil appliance can if it burns poorly or doesn’t vent properly. Electric water heaters can’t, because they burn nothing.

Can a CO alarm go off by mistake?

Rarely, and you can’t tell from inside, so always treat it as real and leave. Alarms past their life can malfunction, which is another reason to replace them on time.

How often should CO alarms be replaced?

Check the date on the back. Many last somewhere around 5 to 10 years and chirp at the end of their life.

Can we use the boiler once the alarm stops?

No. Leave it off until it has been checked, even if the alarm went quiet.

Does opening the windows make it safe?

No. Open windows lower the level for a while but don’t fix the source. Leave the house and let the fire department check.

Can a blocked chimney cause CO even if the boiler runs fine?

Yes. The boiler can run normally while its exhaust spills back into the house, which is why venting is checked at every service.

Should every gas appliance be checked after an alarm?

Yes. The alarm doesn’t say which appliance caused it, so every appliance with a flame is checked, along with the vents and the chimney.

Does a CO alarm replace a smoke alarm?

No, unless it is a combination unit. They detect different things, and every home needs both.

More on safety and savings

Sources

Rather have a plumber look at it?

Send an emergency request and we call you back. Once we confirm by phone, a plumber is at your door within 1 hour.

Get a call back