How to read the gauge
Most hot-water boilers have one round gauge that shows pressure in psi and temperature on the same dial. Read it with the boiler cold, then again after it has run for a while. A hot reading a few psi higher than the cold one is normal.
Steam boilers are different. They run at very low pressure, often one or two psi, so the numbers on this page don’t apply to them. A steam boiler showing 12 psi would be far too high.
Why the pressure goes too high
A failed expansion tank
The expansion tank absorbs the extra volume when the water heats. Once its cushion of air is gone, the pressure jumps every time the boiler fires. A plumber checks the tank’s air charge and replaces the tank if it has failed.
A fill valve that lets water through
The automatic fill valve tops the system up when the pressure drops. If it doesn’t close fully, it keeps pushing city water in until the relief valve opens.
A leaking hot water coil
Some boilers also heat the home’s tap water through a coil inside them. If that coil leaks, the pressure of the house water pushes into the boiler.
Safety first. If the needle is near the relief valve’s rating, usually 30 psi on a home boiler, or the relief valve is discharging, switch the boiler off and send an emergency request. Never cap or block the relief valve.
Pressure still wrong? Get a plumber at your door within 1 hour
Why the pressure drops
- A leak somewhere in the system. Look under the boiler, at the pump, at the valves and at the radiator connections. See boiler leaking water.
- Air was bled from the radiators and the system wasn’t topped up afterwards.
- The fill valve is closed or clogged, so it can’t top the system up.
Low pressure isn’t dangerous by itself, but many boilers lock out below a set pressure to protect themselves, and air gets into the radiators.
What you can safely do
- Write down the cold and hot readings. They help the plumber more than anything else.
- Look for water around the boiler, the pump and the end of the relief valve pipe.
- If your boiler has a manual fill valve and the pressure is low with the boiler cold, top up slowly to the normal range and close the valve. If you aren’t sure which valve it is, leave it alone.
Safety first. Don’t add water to a hot boiler, and don’t drain water to bring the pressure down without finding out why it rose.
How the expansion tank is checked
Most boiler expansion tanks hang from a pipe near the boiler. With the system cold, a plumber checks the air pressure at the valve on the tank and compares it with the system’s fill pressure. A tank that feels heavy and sounds full of water when tapped, or spits water from its air valve, has a failed bladder and is replaced. Older systems may have a plain steel tank in the ceiling that slowly fills with water and has to be drained.
The fill valve and the backflow preventer
The automatic fill valve is set to top the system up to a fixed cold pressure, often around 12 psi. Next to it there is usually a backflow preventer that keeps boiler water from flowing back into the drinking water. Both can clog with sediment or wear out, and both are checked when the pressure behaves strangely.
Why low pressure lets air in
When the pressure at the top of the system drops too low, air can be drawn in at vents and fittings, and radiators on the top floor stop heating first. That is why pressure and air problems often show up together, and why bleeding radiators without topping the system up can make things worse.
When the gauge itself is wrong
Gauges stick too. A needle that never moves, whether the boiler is hot or cold, may simply be a failed gauge. A plumber checks it against a test gauge before anything else is replaced.
A note on steam boilers
A steam boiler is controlled by a pressure switch, often called a pressuretrol, that turns the burner off at a low set pressure, usually around one or two psi in a home. When a steam boiler runs at much higher pressure, radiators heat unevenly, vents spit water and fuel is wasted. The switch and the small looped pipe under it can clog and need cleaning.
What to tell the plumber when you call
- The cold and hot pressure readings.
- Whether the relief valve has dripped or discharged.
- Whether you have been adding water, and how often.
- Any water around the boiler, the pump or the radiators.
Two readings, cold and hot, usually point straight at the expansion tank or the fill valve.
When to call a plumber
- The pressure climbs again after the system cools.
- The relief valve drips or discharges.
- You keep having to top the system up.
- The boiler locks out with a low-pressure code.
Boiler pressure off? Send a request
- A plumber at your door within 1 hour of confirming by phone
- Nights, weekends and holidays
- Anywhere in Philadelphia
Prefer to talk? Call us
Questions people ask
What is normal pressure for a home boiler?
Many hot-water systems in homes run around 12 to 15 psi cold and up to about 20 to 25 psi hot, safely below the usual 30 psi relief valve. Taller houses may need a little more. The label or manual has the exact range for yours.
Why does the pressure go up when the heat is on?
Water expands as it heats, and a working expansion tank keeps that rise small. A big jump toward the relief valve’s rating points to a failed expansion tank.
Why does the pressure drop overnight?
As the system cools, the pressure falls a little, which is normal. A reading that ends up below the usual cold pressure every morning means water is leaving the system somewhere.
Can I drain some water if the pressure is high?
Only as a short-term step on a cool system, and only if you know which valve to use. The pressure will climb again unless the cause is fixed.
Can high pressure damage the boiler?
Repeated spikes wear the relief valve, the expansion tank and the joints in the system. The relief valve keeps it from becoming dangerous, but the cause should still be fixed.
Where is the fill valve?
Usually on the cold water pipe that feeds the boiler, with a small lever on top and a backflow preventer next to it.
Does a steam boiler have a pressure gauge too?
Yes, but it reads in very small numbers, and the pressure control decides when the burner stops. The hot-water ranges on this page don’t apply to it.