What to do right away
Switch the boiler off
Use its service switch, often a switch with a red plate near the boiler or at the top of the basement stairs. That stops it firing while it loses water.
Keep away from the electrics
If water is near the boiler’s wiring, the pump or an outlet, don’t touch them and don’t stand in the water.
Contain it
Put a pan or towels under the drip and move anything stored nearby.
Look before you wipe
Note where the water is and whether it is warm, and take a photo. Fresh drips are the best clue to the source.
Safety first. With the boiler off in winter, let a thin stream run from faucets on outside walls so the pipes don’t freeze.
Where the water is coming from
- The relief valve pipe: water from the pipe on the side of the boiler means the pressure is too high. See boiler pressure too high or too low.
- The pump: drips from the circulator pump’s seal or its flanges. The pump or its gaskets are replaced.
- Valves and fittings: a weeping valve stem, the air vent on top of the boiler or a pipe joint. Usually a simple repair.
- The condensate line: a high-efficiency condensing boiler makes water as it runs and drains it through a small plastic pipe. Water from a loose or blocked condensate line is a repair, not a leaking boiler.
- The boiler body: water from between the sections of a cast-iron boiler, or from the heat exchanger, usually means it has cracked.
- Steam boilers: water around the sight glass, or a boiler that needs water added often, can point to a leak in the boiler or in the return pipes.
How serious is it?
Leaks at valves, the pump, the air vent or the condensate line are repairs, and the boiler keeps going. A crack in the boiler body or the heat exchanger can’t be repaired reliably, and a boiler that keeps losing water corrodes faster. That is when replacement is the honest answer. Our guide on repairing or replacing a boiler explains how to decide.
Why boilers leak
- Age and corrosion, especially at joints and at the base.
- Pressure that runs too high and stresses seals and the relief valve.
- Worn pump seals and valve packings.
- Fresh water added often, which brings in oxygen and speeds up rust inside.
- Sludge and scale inside a system that was never treated or flushed.
Leak or condensation?
A cold boiler starting up on a cold day can drip condensation from the burner area for a few minutes, especially an older one. It stops once the boiler is warm. Water that keeps coming while the boiler is hot, or that collects while it is off, is a leak.
Small leaks don’t stay small
A slow drip makes the system lose pressure, and the fill valve tops it up with fresh water. That fresh water carries oxygen, which corrodes the boiler and the radiators from the inside. Over a winter, a small leak can shorten the life of the whole system.
Leaks at radiators and pipes
- A drip at a radiator valve is usually the packing around the stem, which can be tightened or replaced.
- A leak at a radiator joint, or a corroded pipe under the floor, often shows first as a stain on the ceiling below.
- Steam radiator vents that spit water point to a water level or a tilt problem, not a leaking radiator.
Keeping the house safe while the boiler is off
- Keep faucets on outside walls dripping, and open the cabinet doors under those sinks.
- Close doors to unused rooms and keep the household in the warmest ones.
- Use space heaters only plugged straight into a wall outlet, with space around them, and never while sleeping.
- Take photos of any water damage before cleaning up, and keep the plumber’s report for insurance.
What to tell the plumber when you call
- Where the water is, and whether it is warm.
- Hot water or steam, and gas or oil.
- The pressure reading, and whether you have been adding water.
- How long it has been leaking.
Where the water is and how warm it is already says a lot about which part is failing.
When to call a plumber
- The water is hot, or keeps coming after the boiler is off.
- You can’t tell where it comes from.
- The pressure keeps dropping, or you keep adding water.
- There is rust or water at the base of the boiler body.
Safety first. If you smell gas, leave the house and call PGW at (215) 235-1212 from outside.
Boiler leaking? Send a request
- A plumber at your door within 1 hour of confirming by phone
- Nights, weekends and holidays
- Anywhere in Philadelphia
Prefer to talk? Call us
If it has to be replaced
In Philadelphia, a new boiler needs a mechanical permit from L&I. For households with a low income, the state’s LIHEAP crisis program can help when heating equipment breaks.
Questions people ask
Can I run the boiler while it leaks?
If it is a small drip from a valve and the pressure holds, it may run until the plumber arrives. If the water comes from the boiler body, the pressure keeps dropping or water is near the electrics, keep it off.
Can a cracked boiler be repaired?
Not reliably. Sealants and patches on a cracked heat exchanger or cast-iron section rarely last, and a crack can affect how the boiler burns. Replacement is the safe answer.
Is a leaking boiler a carbon monoxide risk?
Water itself isn’t, but a leak that wets the burner, or a cracked heat exchanger, can affect combustion. A working CO alarm near the boiler and near the bedrooms matters.
Why is there water under my high-efficiency boiler?
Condensing boilers make water by design and drain it through a condensate line, sometimes to a small pump. A blocked or loose line, or a failed pump, makes it look like a leak.
How long does a boiler repair take?
Most valve, pump and fitting repairs are done in one visit when the part is on hand. A replacement takes longer because of the permit, the removal and the start-up.
Who do I call first, PGW or a plumber?
If you smell gas, PGW first, from outside the house. For a water leak with no gas smell, a plumber.
Why doesn’t the pressure drop even though it leaks?
Hot-water systems top themselves up through the fill valve, which can hide a slow leak for months. Steam boilers that need water added more and more often show the same thing.