Water heaters

Water Heater Pilot Light Keeps Going Out? Causes and Fixes

If the pilot lights but goes out again, the heater is pointing at something specific. Most of the time it is one of five things, and two of them you can check without tools.

5 min read

How the pilot stays lit

On most gas tank heaters, a small sensor called a thermocouple sits in the pilot flame. While it is hot, it holds the gas valve open. If the flame stops heating it, the valve shuts off the gas as a safety, and the pilot goes out with it.

Why it keeps going out, most common first

  1. A worn or loose thermocouple

    A thermocouple that is worn, or no longer sitting in the flame, can’t keep the valve open. It is a quick part to replace.

  2. A clogged air intake screen

    Most newer gas water heaters have a sealed burner area with an air screen at the bottom that keeps flammable vapors out. When lint, dust or pet hair cover it, the flame starves for air and goes out.

  3. A weak or dirty pilot flame

    A healthy pilot is steady, mostly blue, and wraps around the tip of the thermocouple. A small, yellow or flickering flame points to a dirty pilot tube.

  4. Drafts or a venting problem

    A draft from an open basement window or door can blow the flame out. A vent that doesn’t draw properly can too, and it also means exhaust may be spilling into the house.

  5. A failing gas control valve

    If a new thermocouple doesn’t help, the gas control valve itself may be failing. It is replaced as one unit.

Pilot still going out? Get a plumber at your door within 1 hour

What you can check safely

  • If the gas control has a status light, count the blinks and match them to the chart on its label.
  • Close any window or door near the heater that lets in a draft.
  • With the heater off, vacuum the dust and lint around its base and from the outside of the air screen.
  • Relight once, following the instructions on the tank, and watch the flame.

Safety first. If you smell gas, don’t relight. Leave the house and call PGW at (215) 235-1212 from outside.

Thermocouple, thermopile or flame sensor

Standard gas heaters use a thermocouple, a thin copper lead running from the pilot to the gas valve. Many newer heaters use a thermopile, a stronger version that also powers the control without electricity, or an electronic flame sensor with a status light. The fix depends on which one yours has, which is why the model number on the label matters.

How to relight safely

  1. Read the label first

    The lighting steps on the tank are specific to your model. Follow them rather than general instructions found online.

  2. Turn it off and wait

    Set the control to Off and wait the time the label gives, often five minutes or more, so any gas can clear.

  3. Light and hold

    Set the control to Pilot, press and hold the knob, and press the igniter until the pilot lights. Keep holding for as long as the label says before letting go.

  4. Turn it to On

    Once the pilot stays lit on its own, turn the control to your temperature setting and listen for the burner to light.

Pilot still going out? Get a plumber at your door within 1 hour

Keep the air intake clear

On heaters with a flammable vapor sensor, air comes in through a screen or a ring of small openings near the bottom. Keep boxes, laundry and lint away from it, and vacuum it from the outside with the heater off. Don’t remove the burner door or take the screen apart: on these sealed designs, that is a job for a plumber.

Keep flammable things away

Gasoline, paint thinner, solvents and aerosol cans stored near a gas water heater are a fire risk, and their vapors can also trip the heater’s safety sensor and shut it down. Store them in another room or outside, and keep a clear space all around the heater.

When the problem is the gas supply

If other gas appliances also flicker or go out, or the stove flame looks weak, the issue may be the gas supply or the piping, not the heater. A kinked flexible connector or a partly closed valve on the heater’s gas line can starve the pilot. After any work on the gas line, air in the pipe can take a few relights to clear.

What to tell the plumber when you call

  • The kind of control: a knob with a pilot window, or a status light.
  • The blink pattern, if it has a light.
  • How long the pilot stays lit after relighting.
  • The brand, model and age from the label.

Thermocouples and gas controls differ by model, so the label details decide which parts come on the first visit.

When to call a plumber

  • The pilot goes out again after one relight.
  • It won’t light at all, or it lights but the burner never comes on.
  • There is soot or scorching around the burner door.
  • The vent pipe on top is loose or rusted through.

Safety first. If a carbon monoxide alarm goes off, get everyone outside and call 911.

Pilot won’t stay lit? Send a request

  • A plumber at your door within 1 hour of confirming by phone
  • Nights, weekends and holidays
  • Anywhere in Philadelphia

Prefer to talk? Call us

Tell us what's wrong

Takes under a minute. For emergencies, someone is at your door within 1 hour of confirming by phone.

How urgent is it?

Worth repairing?

A thermocouple, a pilot assembly or a gas control valve are all replaceable, and the heater keeps going. If the heater is old or the tank is rusting, the money may be better spent on a new one. Our guide on how long a water heater lasts explains how to tell.

Questions people ask

Why does the pilot go out when it is windy?

Strong wind can push air back down the vent and blow out a weak pilot. If it happens often, the vent and its cap should be checked.

Is it dangerous if the pilot keeps going out?

The safety valve stops the gas when the pilot goes out, so gas doesn’t keep flowing. The concern is the cause: venting problems and soot mean the heater isn’t burning properly, and that is where carbon monoxide comes from.

How long does a thermocouple last?

Often several years, but heat wears it out. A pilot that goes out more and more often over a few weeks is a typical sign.

Can I switch to an electric water heater instead?

Yes. It needs a 240-volt circuit with the right breaker and wire, and the gas line to the heater is capped. We do both the plumbing and the electrical side.

Why does the pilot stay lit but the burner won’t come on?

The pilot is fine, but the gas control isn’t sending gas to the burner. It may be set to Pilot, the water may already be at temperature, or the control’s thermostat may have failed.

Does a standing pilot use much gas?

It burns a small amount all the time. Newer heaters with electronic ignition only light when they need to heat.

More on water heaters

Rather have a plumber look at it?

Send an emergency request and we call you back. Once we confirm by phone, a plumber is at your door within 1 hour.

Get a call back