The main groups of codes
- Ignition failure: the unit tried to light and couldn’t. Gas supply, the igniter or air.
- Flame loss: it lit, but the flame went out. Gas pressure, the flame sensor, wind or venting.
- Air supply or exhaust: something blocks the intake or the vent outside.
- Overheating: the heat exchanger got too hot, often from scale or low flow.
- Water flow or freeze protection: not enough flow, a clogged filter or a cold snap.
- Scale: minerals coating the heat exchanger. It needs descaling.
Common Rinnai codes
- 10: air supply or exhaust blockage.
- 11: no ignition, the heater isn’t turning on.
- 12: flame failure, it lit but couldn’t hold the flame.
- LC: lime scale build-up in the heat exchanger. It is the only code that lets the unit keep running, alternating with the temperature on the display, but it needs a flush.
What you can safely check
Note the code and the model
Write down the code, the brand and the model from the label, and whether the code comes back right away or after a while.
Check gas and power
Make sure the gas valve to the unit is open, other gas appliances work and the unit has power.
Look at the vent outside
Clear snow, leaves, a nest or anything stacked against the intake and exhaust. A grill or a dryer vent placed too close can also cause trouble.
Clean the inlet filter
With the water to the unit shut off, remove and rinse the small screen where the cold water comes in.
Reset it once
Turn the unit off and on, or use the reset in the manual. If the same code comes back, leave it off and call.
Safety first. If you smell gas near the unit, don’t reset it. Leave the house and call PGW at (215) 235-1212 from outside.
Code still showing? Get a plumber at your door within 1 hour
Scale: the cause behind many codes
Hard water leaves minerals inside the heat exchanger. As the coating builds, the unit runs hotter, the flow drops and codes start to appear, from scale warnings to overheating and flame problems. Flushing the heat exchanger with a descaling solution, usually once a year, prevents most of them. Units that are never descaled tend to fail years early.
When the gas line is too small
A tankless heater draws a lot of gas at once. If the gas line feeding it is too small or too long, the unit may light and then lose its flame when other appliances run, or show a code only at high flow. That usually shows soon after installation or after another gas appliance is added, and the fix is a larger gas line, not a new heater.
Codes in a cold snap
Units on outside walls can throw freeze or flow codes in hard cold. Most have built-in freeze protection that needs power, so a tripped breaker or a power outage leaves them exposed. Keep the power on, and if the vent pipes run outside, check that snow hasn’t covered them.
How to reset a tankless heater
Most units reset by switching off the power at the unit or its breaker for a minute and back on, or with a button on the controller. The manual gives the exact steps. Some codes clear themselves when the problem goes away; others stay until someone resets them, which is the unit asking for a check.
The code history helps
Many units store their last several codes. A plumber can read that history to see whether the same fault keeps coming back, which often says more than the code showing today.
How descaling works
Isolate the unit
The gas and power are turned off and the water service valves on the unit are closed.
Circulate the solution
A small pump runs a descaling solution through the heat exchanger for the time the manufacturer gives.
Flush and clean
The solution is flushed out with fresh water, and the inlet filter is cleaned.
Restart and check
The unit is restarted and its temperature and flow are checked.
Units installed with service valves make this a simple yearly job.
Code still showing? Get a plumber at your door within 1 hour
Keep the outside vent clear
- Keep plants, fences and stored items as far from the vent as the manual requires.
- Don’t place a grill, a dryer vent or another exhaust next to the intake.
- Clear snow after storms, especially from low vents.
What to tell the plumber when you call
- The exact code, the brand and the model.
- When it shows: at start, after a few minutes, or only at one tap.
- When the unit was last descaled.
- Whether other gas appliances work normally.
The code plus the model number usually tells the plumber which part to bring.
When to call a plumber
- The same code returns after one reset.
- Ignition or flame codes keep coming.
- You see an overheating code.
- Any code comes with a gas smell, soot or scorch marks.
Tankless error code? Send a request
- A plumber at your door within 1 hour of confirming by phone
- Nights, weekends and holidays
- Anywhere in Philadelphia
Prefer to talk? Call us
Questions people ask
Can I keep using the unit with an LC code?
For a short while, since it keeps running, but book the descaling soon. Left alone, the scale leads to more serious codes and shutdowns.
Why does the code show only at one faucet?
Low-flow faucets may not draw enough water for the unit to fire steadily. Opening the tap further, or cleaning the faucet’s aerator, often helps.
Do error codes clear on their own?
Some reset when the problem clears, others need a manual reset. A code that keeps coming back is the unit asking for service.
Is a flame failure code dangerous?
The unit shuts off the gas when it loses its flame, which is the safety doing its job. The cause, like venting or gas pressure, still has to be found.
Can a power or gas outage cause an error code?
Yes. After an outage, some units show a code or need a reset, and an interruption in the gas can trigger an ignition failure until air clears from the line.
Should I call the manufacturer or a plumber?
For warranty questions, the manufacturer. For a unit that won’t run, a plumber who knows the brand can find the cause on site, and can also tell you what to ask the manufacturer.
Related services
- Tankless Water Heater Repair in Philadelphia
- Water Heater Repair in Philadelphia
- Gas Line Repair in Philadelphia