Narrow it down
Compare hot and cold
If only the hot side is weak, the cause is on the hot line or the water heater. If both are weak, it is the fixture or its shared supply.
Check nearby fixtures
If the sink next to a weak shower is fine, the cause is in the shower valve or head.
Think about timing
Low pressure right after a water shutoff, a repair or a new water heater often means debris loosened and lodged somewhere.
Check the valves
Make sure the shut-off valves under the sink or behind the fixture are fully open.
Weak flow at one fixture? Get a plumber at your door within 1 hour
Start with the aerator
The aerator is the small screen at the tip of the faucet spout. It is the first narrow spot the water reaches, so it catches whatever is in the line. Unscrew it by hand or with a cloth-wrapped pliers, rinse the screen and look at what comes out.
The Philadelphia Water Department notes that one of the most common sources of white or gray particles in faucet aerators is the hot water heater. If you find those, the water heater may be shedding scale or a broken-down dip tube, and other hot taps may follow.
Shower heads
Philadelphia water is typically around 100 to 150 parts per million of hardness, about 6 to 9 grains per gallon, according to PWD. Over time those minerals build up in the small nozzles of a shower head. Unscrew the head and soak it in vinegar, or rub the rubber nozzles to break the scale loose. Many heads also have a small screen and a flow restrictor at the inlet that can clog.
Cartridges and valves
- A faucet or shower cartridge with grit lodged in it restricts flow, often on one side.
- A worn compression washer can partly block the flow on older faucets.
- A shower valve’s inlet screens, on models that have them, can clog after a shutoff.
- A pressure-balancing valve that is sticking can limit flow when the cold or hot side drops.
Supply lines and valves under the sink
- A shut-off valve that is only partly open, often after recent work.
- An old multi-turn valve whose washer has come loose and partly blocks the opening.
- A kinked or crushed supply line.
- A plastic supply line that has collapsed inside.
Our guide to a shut-off valve that won’t turn or leaks covers those valves.
Pull-down and pull-out kitchen faucets
These faucets have extra places to clog: a check valve or screen where the hose connects, the spray head’s own screen, and a hose that can kink under the sink. If the flow is strong with the spray head removed, the head is the problem.
A toilet that refills slowly
A toilet that takes a long time to refill has the same kinds of causes: a partly closed shut-off behind it, a worn fill valve or a clogged screen at the fill valve inlet. Cleaning or replacing the fill valve usually restores the refill speed.
When the pipe itself is the problem
In older Philadelphia homes, a single bathroom or kitchen may still be fed by galvanized steel pipe even when other lines have been replaced with copper. Galvanized pipe narrows inside as it corrodes, and the run to one fixture can choke down to a trickle. EBMUD, the East Bay water utility, notes that old, corroded galvanized pipes can cause low water pressure and discolored water. If cleaning the fixture doesn’t help and the house has some galvanized pipe, that line is the likely culprit; see our guide to galvanized pipes in older Philly homes.
If only the hot side is weak
- Sediment or dip tube particles from the water heater.
- A partly closed valve on the water heater’s outlet or inlet.
- Scale in the hot side of a cartridge or shower valve.
- With a tankless heater, a clogged inlet filter or scale in the heat exchanger.
If it turns out to be more than one fixture
If you find several fixtures weak, the cause is more likely the main valve, the meter, a pressure-reducing valve or a leak. Our guide to low water pressure in the whole house covers those.
What to tell the plumber when you call
- Which fixture is weak, and whether it is hot, cold or both.
- When it started and whether anything changed: a shutoff, a repair, a new water heater.
- What you found in the aerator or shower head.
- Whether the shut-off valves are fully open.
- Whether the house has old galvanized pipe.
If the low pressure came with a leak or a wet wall, say that first.
When to call a plumber
- Cleaning the aerator or shower head didn’t help.
- The cartridge or valve needs replacing.
- The shut-off valve won’t open fully or leaks.
- Grit keeps coming back.
- The line to the fixture is old galvanized pipe.
Low pressure at one fixture? Send a request
- A plumber at your door within 1 hour of confirming by phone
- Nights, weekends and holidays
- Anywhere in Philadelphia
Prefer to talk? (215) 261-5725
Questions people ask
Why did pressure drop at one faucet after a water shutoff?
Turning the water back on stirs up debris, which often lodges in the first aerator or cartridge it reaches. Clean the aerator first.
Can a shower head reduce pressure on purpose?
Yes. Many have flow restrictors to save water. A clogged restrictor or screen makes it much worse.
Why is only the hot water weak?
The cause is on the hot side: sediment from the water heater, a partly closed valve or scale in the hot side of the valve.
Will a new faucet fix it?
Only if the faucet is the problem. Check the aerator, the valves and the supply line first.
Can I remove a flow restrictor?
Shower heads and faucets are sold with flow limits to save water. Clean the restrictor rather than removing it; a much stronger flow also uses more hot water.
Why is the shower weak upstairs but fine downstairs?
If several upstairs fixtures are weak, the riser feeding that floor may be narrowed old pipe, or pressure is low for the whole house.
How do I remove a stuck aerator?
Most unscrew by hand. Wrap a cloth around a stuck one before using pliers; some recessed aerators need a small key from the faucet maker.
Is low pressure at one fixture an emergency?
No, unless it came with a leak or a wet wall. It can wait for a convenient repair.
Can old pipes cause low pressure at one fixture?
Yes. A corroded galvanized branch can narrow until only one fixture is affected.
Related services
- Faucet and Fixture Repair in Philadelphia
- Shut-Off Valve Replacement in Philadelphia
- Water Line Repair in Philadelphia